Fundamental Fluids  FM1000  Fundamental Fluids                                                     FM1000



                                                            Flow Sensor                                             LOCKTRONICS
 Main Workstation                                            The  Flow  sensor  module  houses  a  calibrated  turbine

                                                             flow sensor. It is used to provide flow rate readout in
 The  main  workstation  is  built  of  rugged  steel  and   the app and on the control module screen.
 LOCKTRONICS
 has  a  built-in  panel  which  allows  you  to  easily  clip
 on the required component. Two water tanks, with a          It can measure 0-30l/min
 combined capacity of 3L, along with inbuilt connectors,     It  has  robust  brass  fittings  for  repeated  assembly/
 allows  students  to  quickly  set  up  each  experiment.   disassembly.
 When  in  storage,  the  flow  pipes  drop  down  into  the
 frame, all components are stored within, the drip tray
 doubles as a back panel to enhance protection.                                                                     ELECTRICAL MACHINES

          Bourdon Gauge

          The  Bourdon  gauge  calibration  module  is  used  to
 ELECTRICAL MACHINES
          compare  a  known,  dead-weight  acting  through  a
 Control Box  piston/cylinder of known diameter with the reading on
          the Bourdon gauge.
 Working with a PC connection, the control box is the   The  apparatus  allows  students  to  determine  the
 brain of the apparatus. Allowing simultaneous control   accuracy  of  the Bourdon  gauge  and  highlights  the
 of 2 pumps, while taking readings from 2 flow and 2   limitations of using these devices.
 pressure  sensors,  the  LCD  screen  gives  students  an                                                          FUNDAMENTAL FLUIDS
 instantaneous readout. The readings are passed from
 the control box to the PC software, which plots results
 for student analysis. The data can also be logged and
 loaded into Excel for further investigation by students.     Multitube Manometer
 FUNDAMENTAL FLUIDS
                                                              The   multitube   manometer     module    permits
                                                              comparative pressure measurement between 0 and
                                                              120mm of water (0-1200Pa).
                                                              The module features:
                                                              • Three  input  pressure  ports  at  the  bottom,  each
 Pump Module                                                   connecting to a single vertical limb.
                                                              • One reference pressure port that is common to all   FUNDAMENTAL MECHANICS
 The Pump module has an operating voltage of 6-24v             three limbs at the top.
 and produces a free-flow flow rate of 13 litres/min. It
 works alongside the control box, to pump water around        • A pipette filler (supplied) as a convenient method of
 the apparatus. It features brass connection points for        applying  a  reference  pressure  to  the  top  pressure
 increased longevity                                           port.
                                                              The pressure ports are self-sealing, push-in fittings and
 FUNDAMENTAL MECHANICS
                                                              connections are made using 4mm push-in pneumatic
                                                              tubing. This allows direct comparative measurements
                                                              to be made between the three input pressure ports.



 Differential Pressure Sensor


 The  Differential  pressure  sensor  module  is  used  to   U-Tube & Inclined Manometer
 measure pressure in the fluid circuits, it features:
 •  True wet/wet differential sensing  The U-tube and inclined manometer has a measurement
 •  Easy-to-use, built-in air bleeding system  range of 0-110mm.
 •  Pressure sensing range 0-30 PSI (0-200000 Pa)  4mm  tubing  is  attached  to  the  pressure  ports  using
 •   Robust  construction,  simple  push  fit  fittings  using   easy-to-use push-in fittings.  The inclined manometer
          indexes to positions at 30°,60° and 90° from horizontal.
 4mm tube




 20  Copyright © 2023 Matrix Technology Solutions Limited  Copyright © 2023 Matrix Technology Solutions Limited   21
   16   17   18   19   20   21   22   23   24   25   26