Fundamental Fluids                                                                        FM1000                       Fundamental Fluids                                                                        FM1000



                                                                                                                                                                                   Flow Sensor                                              LOCKTRONICS
                                                             Main Workstation                                                                                                       The  Flow  sensor  module  houses  a  calibrated  turbine

                                                                                                                                                                                    flow sensor. It is used to provide flow rate readout in
                                                             The  main  workstation  is  built  of  rugged  steel  and                                                              the app and on the control module screen.
   LOCKTRONICS
                                                             has  a  built-in  panel  which  allows  you  to  easily  clip
                                                             on the required component. Two water tanks, with a                                                                     It can measure 0-30l/min
                                                             combined capacity of 3L, along with inbuilt connectors,                                                                It  has  robust  brass  fittings  for  repeated  assembly/
                                                             allows  students  to  quickly  set  up  each  experiment.                                                              disassembly.
                                                             When  in  storage,  the  flow  pipes  drop  down  into  the
                                                             frame, all components are stored within, the drip tray
                                                             doubles as a back panel to enhance protection.                                                                                                                                 ELECTRICAL MACHINES

                                                                                                                                 Bourdon Gauge

                                                                                                                                 The  Bourdon  gauge  calibration  module  is  used  to
   ELECTRICAL MACHINES
                                                                                                                                 compare  a  known,  dead-weight  acting  through  a
          Control Box                                                                                                            piston/cylinder of known diameter with the reading on
                                                                                                                                 the Bourdon gauge.
          Working with a PC connection, the control box is the                                                                   The  apparatus  allows  students  to  determine  the
          brain of the apparatus. Allowing simultaneous control                                                                  accuracy  of  the Bourdon  gauge  and  highlights  the
          of 2 pumps, while taking readings from 2 flow and 2                                                                    limitations of using these devices.
          pressure  sensors,  the  LCD  screen  gives  students  an                                                                                                                                                                         FUNDAMENTAL FLUIDS
          instantaneous readout. The readings are passed from
          the control box to the PC software, which plots results
          for student analysis. The data can also be logged and
          loaded into Excel for further investigation by students.                                                                                                                   Multitube Manometer
   FUNDAMENTAL FLUIDS
                                                                                                                                                                                     The   multitube   manometer     module    permits
                                                                                                                                                                                     comparative pressure measurement between 0 and
                                                                                                                                                                                     120mm of water (0-1200Pa).
                                                                                                                                                                                     The module features:
                                                                                                                                                                                     • Three  input  pressure  ports  at  the  bottom,  each
                                                            Pump Module                                                                                                               connecting to a single vertical limb.
                                                                                                                                                                                     • One reference pressure port that is common to all   FUNDAMENTAL MECHANICS
                                                             The Pump module has an operating voltage of 6-24v                                                                        three limbs at the top.
                                                             and produces a free-flow flow rate of 13 litres/min. It
                                                             works alongside the control box, to pump water around                                                                   • A pipette filler (supplied) as a convenient method of
                                                             the apparatus. It features brass connection points for                                                                   applying  a  reference  pressure  to  the  top  pressure
                                                             increased longevity                                                                                                      port.
                                                                                                                                                                                     The pressure ports are self-sealing, push-in fittings and
   FUNDAMENTAL MECHANICS
                                                                                                                                                                                     connections are made using 4mm push-in pneumatic
                                                                                                                                                                                     tubing. This allows direct comparative measurements
                                                                                                                                                                                     to be made between the three input pressure ports.



         Differential Pressure Sensor


         The  Differential  pressure  sensor  module  is  used  to                                                               U-Tube & Inclined Manometer
         measure pressure in the fluid circuits, it features:
         •  True wet/wet differential sensing                                                                                    The U-tube and inclined manometer has a measurement
         •  Easy-to-use, built-in air bleeding system                                                                            range of 0-110mm.
         •  Pressure sensing range 0-30 PSI (0-200000 Pa)                                                                        4mm  tubing  is  attached  to  the  pressure  ports  using
         •   Robust  construction,  simple  push  fit  fittings  using                                                           easy-to-use push-in fittings.  The inclined manometer
                                                                                                                                 indexes to positions at 30°,60° and 90° from horizontal.
            4mm tube




    20                                 Copyright © 2023 Matrix Technology Solutions Limited                                                                   Copyright © 2023 Matrix Technology Solutions Limited                       21
   15   16   17   18   19   20   21   22   23   24   25