Page 20 - Aerospace Training Range Brochure 2023 WEB
P. 20

Fundamental Fluids                                                                        FM1000                       Fundamental Fluids                                                                        FM1000
                                                                                                                                 Fundamental Fluids


                                                                                                                                                                                      Fluids Configure Application                          MODULE 2.0

   MODULE 2.0
                                                              Losses in Bends Module                                                                                                  Each of the sensors are calibrated prior to shipping
                                                                                                                                                                                      and the electronic control module is sent with these
                                                              The losses in bends module consists of a clearly visible                                                                calibration values.
                                                              fluid path with 3 different 90° bend geometries.                                                                        The user can re-calibrate each of the sensors in situ   MODULE 3.0
                                                              Each of the bends  have  self-sealing  pressure  ports                                                                  using the fluids configure application.
                                                              before and after each bend so the pressure drop can                                                                     This application also allows the user to alter the
   MODULE 3.0
                                                              be measured using the multitube manometer module.                                                                       filter that is applied to the instantaneous sensor
                                                                                                                                                                                      readings.
                                                                                                                                                                                      Each of the buttons shown above opens a dialog        MODULE 4.0
                                                                                                                                                                                      box for changing the values for each of the settings.
   MODULE 4.0
          Viscosity Apparatus

          The viscosity apparatus consists of a 100mm diameter
          clear acrylic tube filled with vegetable glycerine.                                                                                                                                                                               MODULE 5.0
          This assembly is housed in a sturdy metal enclosure
          which protects it whilst in storage or being transported.
   MODULE 5.0
          It features  ¼-turn valves  at the top  and  bottom  to
          enable  releasing  and  retrieving  spherical  samples
          used in the experiment.
          The experiment demonstrates Stoke’s law. Students                                                                                                                                                                                 MODULE 8.0
          determine the viscosity of the glycerine by measuring
   MODULE 8.0
          the terminal velocity of spherical samples through the
          fluid.


                                                             Centre of Pressure Module                                                                                                                                                      MODULE 11.0

                                                             The Centre of pressure module is used for determining
   MODULE 11.0
                                                             the centre of pressure of partially and fully submerged
                                                             surfaces.  This  experiment  is  carried  out manually by
                                                             students who are able to take readings and plot them
                                                             within the curriculum for analysis.













          Venturi Tube Module

          The  Venturi  tube module  is used  to investigate                                                                     Fluids Control Application
          Bernoulli’s principle.
          The flow section is constricted resulting in a pressure                                                                Readouts for pumps show instantaneous voltage, Current and Power as well as live displays for flow and
                                                                                                                                 pressure sensors.
          drop.
          Pressure  ports  at  the widest  and  narrowest  section                                                               Manual control of the pumps is provided by clicking and dragging the red slider, alternatively the exact pump
                                                                                                                                 voltage(s) can be set using the override button
          permit  attaching  the  differential  pressure  sensor  for
          automated readings or the manometer module can be                                                                      User can alter parameters to suit their experiment. The sweep function automatically sets the pump voltage
          attached to enable manual readings.                                                                                    to 24V and decreases in steps defined by the user. Data for each sensor is recorded and the resulting graph is
                                                                                                                                 plotted live. This data can also be logged in a time stamped .CSV file for more thorough analysis.