Component: Injector (CAN) (Simulation)

From Flowcode Help
Revision as of 15:58, 16 January 2014 by JonnyW (talk | contribs) (XML import)
Jump to navigationJump to search
Author Matrix Ltd
Version 1.0
Category Simulation
This inherits from Data Injector


Image Injector (CAN) component

Comms data injector to allow CAN message identifiers to be decoded to specific message strings. Uses an external CSV file to specify the IDs and descriptive strings.

Examples

No additional examples


Downloadable macro reference

This component does not contain any downloadable macros

Simulation macro reference

This component inherits simulation macros from Data Injector

TxByte

Puts a byte onto the comms channel.

CAN packet is inserted into injector like this:

ID3, ID2, ID1, ID0, D7, D6, D5, D4, D3, D2, D1, D0, \n

Parameters

BYTE DataByte


Return value

This call does not return a value


RxByte

Attempt to receive a byte back from the injector

This call is provided by Data Injector

Parameters

This macro has no parameters


Return value

BYTE


GetTxConsoleHandle

Gets the handle to the console allowing data displaying on the panel etc.

This call is provided by Data Injector

Parameters

This macro has no parameters


Return value

HANDLE


ChangeState

Changes the state for I2C or SPI type comms where the data bytes along are not enough to go on.

This call is provided by Data Injector

Parameters

BYTE NewState
Assigns new state, 0=default


Return value

This call does not return a value


GetRxConsoleHandle

Gets the handle to the console allowing data displaying on the panel etc.

This call is provided by Data Injector

Parameters

This macro has no parameters


Return value

HANDLE


InitialiseInjector

Sets up the injector ready to receive commands or send data

Parameters

<- STRING InjectorName
Name of the console that will be created
This parameter may be returned back to the caller


Return value

BYTE


GetConsoleHandle

Gets the handle to the console allowing data displaying on the panel etc.

Parameters

BYTE HandleIndex
Selects which console handle to obtain - 0=ID/Data 1=ID Meanings


Return value

HANDLE



Property reference

Circular Buffer Size

This property is of type Unsigned integer and can be referenced with the variable name CircularBufferSize.

Number of bytes that can be held in the injector's circular buffer

Termination Character

This property is of type Fixed list of ints and can be referenced with the variable name TermChar.

Used to signify the end of a message, in the case of CAN it will end a specific identifier message

CSV ID File

This property is of type Filename and can be referenced with the variable name CSVFile.

Location of comma seperated ID description file.

e.g.

ID,Description

1,Door Open

2,Door Closed

3,Window Open

4,Window Closed

1023,System Disable

1024,System Enable