Difference between revisions of "Selecting Compiler Options (ARM)"

From Flowcode Help
Jump to navigationJump to search
 
Line 20: Line 20:
 
Default:
 
Default:
  
<code>'''$(appdir)compilers\arm\batchfiles\arm7comp.bat'''</code>
+
<code>'''$(compilerstarm)batch\stm32comp.bat'''</code>
  
  
Line 29: Line 29:
 
Default:
 
Default:
  
<code>'''"$(target)" "$(outdir)"'''</code>
+
<code>'''""$(target)" "$(outdir)" "$(chipalt)" "$(family)" "$(lscript)" "$(clock)" "$(romsize)" "$(ramsize)"'''</code>
  
  
Line 54: Line 54:
 
Default:
 
Default:
  
<code>'''$(appdir)compilers\arm\batchfiles\arm7link.bat'''</code>
+
<code>'''$(appdir)tools\DoNothing\DoNothing.exe'''</code>
  
  
Line 88: Line 88:
 
Default:
 
Default:
  
<code>'''$(appdir)tools\mLoader\mLoader.exe'''</code>
+
<code>'''$(compilerstarm)batch\stm32prog.bat'''</code>
  
  
Line 97: Line 97:
 
Default:
 
Default:
  
<code>'''"$(outdir)$(target).bin"'''</code>
+
<code>'''""$(outdir)" "$(target)"'''</code>
  
  
Line 108: Line 108:
  
 
This box should be left empty. Configuration parameters are set and downloaded from the Build > Configure menu.
 
This box should be left empty. Configuration parameters are set and downloaded from the Build > Configure menu.
 
 
Note: The above parameters assume you are using the AVRDUDE programming application and AVRISPmkII programmer. If you are using an alternative programming application or programmer you will need to consult the relevant documentation for the required parameters and settings.
 
 
 
==File Viewer==
 
[[File:Gen_Compiler_Options_File_Viewer_ARM.png|right|524x400px]]
 
'''File Viewer location'''
 
 
Sets the File viewer location for viewing C and Assembly files.
 
 
The default is empty, this activates the use of the internal C code viewer.
 
 
Default:
 
 
<code>'''C:\Windows\Notepad.exe'''</code>
 
 
 
'''File Viewer parameters'''
 
 
Adds command line parameters for the File viewer program
 
 
Default Assembly file viewer:
 
 
<code>'''$(outdir)$(target).lst'''</code>
 
 
Default external program to view source files:
 
 
<code>'''$(outdir)$(target).c'''</code>
 

Latest revision as of 10:41, 14 November 2018

<sidebar>Sidebar: Managing Compiler Options</sidebar> Allows users to set the Compiler options.


Options list

See the Managing Compiler Options topic for more information on using this feature.


Substitute variables used by Flowcode are the same for all platforms.


Compiler

Gen Compiler Options Compiler ARM.png

Compiler location

Sets the location of the file controlling compilation

Default:

$(compilerstarm)batch\stm32comp.bat


Compiler parameters

Adds command line parameters when called from Flowcode

Default:

""$(target)" "$(outdir)" "$(chipalt)" "$(family)" "$(lscript)" "$(clock)" "$(romsize)" "$(ramsize)"









Linker/Assembler

Gen Compiler Options Linker Assembler ARM.png

Linker/Assembler location

Sets the location of the file controlling linking and assembly

Default:

$(appdir)tools\DoNothing\DoNothing.exe


Linker/Assembler parameters

Adds command line parameters when called from Flowcode

Default:

<empty>

There are no default parameters








Programmer

Gen Compiler Options Programmer ARM.png

Programmer location

Sets the location of the file controlling the programming of the target device

Default:

$(compilerstarm)batch\stm32prog.bat


Programmer parameters

Adds command line parameters when called from Flowcode

Default:

""$(outdir)" "$(target)"


Use programmer to set configuration options

This box should be left unchecked


Configuration parameters

This box should be left empty. Configuration parameters are set and downloaded from the Build > Configure menu.